Laboratory Sensors

XS SENSORS: IDEAL FOR YOUR ELECTROCHEMICAL MEASUREMENTS

The pH electrode is a sensor with a glass membrane that is sensitive to H+ ion activity. It transforms this activity into a proportional electrical signal.

This electrical signal via a digital instrument (pH meter) is transformed into pH units.

The electrodes marketed by Giorgio Bormac srl are produced by a leading Swiss Manufacturer and are synonymous with precision and quality. The line of electrodes marketed includes a wide range of electrodes suitable for a wide variety of applications ranging from the food industry to the chemical industry, from environmental analysis to quality control; they are suitable for both laboratory measurements and complex industrial processes. Contrary to what is sometimes thought, there is no universal electrode, but there are different electrodes specific to each application. Choosing a suitable electrode is critical to the quality of the measurement itself and to the life of the electrode; using an unsuitable electrode can result in measurement error and significantly reduce the life of the electrode.

The pH sensor consists of 2 electrodes, a measuring electrode and a reference electrode. The measuring electrode has a glass membrane, which is sensitive to H+ ion activity.

The reference electrode is constructed of a silver wire coated with silver chloride immersed in a liquid or semisolid electrolyte. The advancement of technology has made it possible to combine the 2 electrodes into a single body, the sensor built with this technology is called a combined monotubular electrode. The electrode, when measuring, should operate in a vertical position, with open side refill cap (only for electrodes with refillable electrolyte) with the membrane and side ceramic diaphragm fully immersed in the sample. Once immersed, it should be shaken for a few seconds and wait for measurement stability. When the measurement is finished, wash the electrode with distilled water, dry it with paper, without rubbing, and store it in the storage solution. It is important not to store the electrode in distilled water, as it makes the measurement very slow, and irreparably damages the electrode.

The pH electrode is an active sensor; it generates a potential, so it depletes its effectiveness over time. Indicatively, the average lifespan of an electrode is one to three years at room temperature, while at high temperatures it is drastically reduced.

Another factor that determines the life of the electrode is the aggressiveness of the sample in which it is immersed; opposite extremes of measurement ( pH 0-2 and pH 12-14) reduce the life and efficiency of the measuring membrane.

Products

77 products available in this category.

XS Sensor Standard KF S7

XS Sensor Standard KF S7

S7 screw head. Glass body. Maintenance-freeDouble platinum for KF and SO2 titrationDimensions (LxØ) mm 120X12

Cod: 32200523 Details
XS Sensor Flow Ag

XS Sensor Flow Ag

S7 screw head. Glass body.Teflon diaphramElectrode for argentometric titrations.Dimensions (WxD) mm 120X12- Temperature 0...80 °C

Cod: 32200543 Details
XS Sensor 2-Pore steel T DIN

XS Sensor 2-Pore steel T DIN

Steel body. S7 head.Polymer filling, maintenance-free. 6 mm tip for penetration measurements. Ideal for meat.Dimensions (WxD) mm 50x6 - pH 0...14 - Temperature 0...80 °C

Cod: 32200643 Details
XS Sensor 2-Pore steel S7

XS Sensor 2-Pore steel S7

Steel body. S7 head. Polymer filling, maintenance-free. 6 mm tip for penetration measurements. Ideal for meat.Dimensions (WxD) mm 50x6 - pH 0...14 - Temperature 0...80 °C

Cod: 32200653 Details
XS Sensor Plast ORP S7

XS Sensor Plast ORP S7

S7 screw head, epoxy body.Maintenance-free gel filling. Porous ceramic septum.Dimensions (WxD) mm 120X12 - Temperature 0...60 °C

Cod: 32200663 Details
XS Sensor Plast ORP BNC

XS Sensor Plast ORP BNC

S7 screw head, epoxy body.Maintenance-free gel filling. Porous ceramic septum.Dimensions (WxD) mm 120X12 - Temperature 0...60 °C

Cod: 32200673 Details
2-Pore T with two PT1000 banana plugs

2-Pore T with two PT1000 banana plugs

Cod: 32200693 Details
XS Sensor 2-Pore F TEMP BNC

XS Sensor 2-Pore F TEMP BNC

Combined pH electrode, screw head S7. Plastic body (PEEK) and glass. Polymer filling, maintenance-free, with double open hole. Thanks to the 6 mm tip it is ideal for meat and cheese and penetration measurements.Dimensions (WxD) mm 35x6 - pH 0...14 -

Cod: 32200703 Details
XS Sensor 2-Pore F TEMP DIN (Pt1000)

XS Sensor 2-Pore F TEMP DIN (Pt1000)

Combined pH electrode, screw head S7. Plastic body (PEEK) and glass. Polymer filling, maintenance-free, with double open hole. Thanks to the 6 mm tip it is ideal for meat and cheese and penetration measurements.Dimensions (WxD) mm 35x6 - pH 0...14 -

Cod: 32200713 Details
XS Sensor Flow T BNC NTC 30K

XS Sensor Flow T BNC NTC 30K

Combined pH electrode, screw head S7. Glass body. Refillable 3M KCl electrolyte. Collar diaphragm for measurements in suspensions and low conductivity samples. With serial number and certificate.Dimensions (WxD) mm 120x12 - pH 0...14 - Temperature

Cod: 32200723 Details
XS Sensor Flow T DIN PT 1000

XS Sensor Flow T DIN PT 1000

Combined pH electrode, screw head S7. Glass body. Refillable 3M KCl electrolyte. Collar diaphragm for measurements in suspensions and low conductivity samples. With serial number and certificate.Dimensions (WxD) mm 120x12 - pH 0...14 - Temperature

Cod: 32200733 Details
XS Sensor Food T BNC

XS Sensor Food T BNC

Cod: 32200753 Details