pH 60 VioLab benchtop pHmeter - 201T Electrode

Item: 50101092


Professional bench pH meter with innovative high definition color LCD display, with possibility of brightness adjustment.
pH, mV, ORP measurement, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration on 1 point.
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels. GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic Data Logger with the possibility of downloading data to PC via micro-USB. Data-Link software freely downloadable from www.giorgiobormac.com.
Connection to external printer via RS232 connector.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.1 - 0.01 pH)
mV: -1000 ... + 1999 (0.1 - 1 mV)
Temperature: -10 ... 110.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, USB cable, power supply and instructions for use.

Complete with XS 201T electrode, with integrated temperature sensor.

Data sheet

Regulations

Regulations

CE

Performance

Accuracy (pH)

± 0,02

Accuracy (Temperature)

± 0,5 °C

mv measuring range (max.)

+ 1900

mv measuring range (min.)

- 1000

ORP measuring range (max.)

+ 1900

ORP measuring range (min.)

- 1000

ORP resolution

0,1 mV

pH measuring range (max.)

+ 16,00

pH measuring range (min.)

- 2,00

pH resolution

0,01

Temperature compensation

0,0...100,0 °C

Temperature measuring range (max.)

+ 110,0 °C

Temperature measuring range (min.)

- 10,0 °C

Temperature resolution

0,1 °C

Working temperature (max.)

+ 45 °C

Working temperature (min.)

0 °C

Feature

Calibration report

Yes, printable

DHS compatible

Yes

Display

Backlight coloured high definition LCD

Display

Backlight coloured high definition LCD

GLP

Yes

GLP

Yes

GLP calibration

Yes

Inputs

BNC - RCA

IP protection

IP 54

Memory / Datalogger

1000 data

Output

Micro USB - RS 232

Output

Micro USB - RS 232

PC connection

Yes

Points of calibration ORP

1

Points of calibration pH

1...3

Stability criteria

3 levels

Standard approved pH

USA - NIST - 2 custom values

Timer calibration due

Yes

Supply

Power supply

100 - 240 V / 50 - 60 Hz

Dimension and Weight

Dimension (LxWxH)

160 x 140 x 45 mm

Weight

380 g