PC 80+ DHS STIRRER Without electrode Without CELL

Item: 50004272


PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement rangepH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Without pH electrode and no cell, with cable S7/BNC, temperature probe NT 55, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars, software for downloading data and power supply.


Data sheet