PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement rangepH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);


Without pH electrode, cable S7 / BNC, temperature probe NT 55, with cell conductivity VPT 1 glass Platinum 2-electrode(C = 1) with temperature probe integrated, support holders, magnetic stirrer with adjustable speed, buffers coloured,glasses for calibration with stirring bars, software for downloading data and power supply.


Data sheet

Regulations

Regulations

CE

Performance

Accuracy (Cond)

± 1% f.s.

Accuracy (pH)

± 0,02

Accuracy (Resistivity)

± 1% f.s.

Accuracy (Salinity)

± 1% f.s.

Accuracy (TDS)

± 1% f.s.

Accuracy (Temperature)

± 0,2 °C

Cond measuring range (max.)

1000 mS

Cond measuring range (min.)

0,00 µS

Cond resolution

0,01 / 0,1 / 1 µS/cm (automatic scale)

Ion measuring range (max.)

19999 mg/l

Ion measuring range (min.)

0,001 mg/l

ORP measuring range (max.)

+ 2000

ORP measuring range (min.)

- 2000

ORP resolution

1 / 0,1 mV

pH measuring range (max.)

+ 20,00

pH measuring range (min.)

- 2,00

pH resolution

0,1 / 0,01 / 0,001

Reference temperature (max.)

+ 30 °C

Reference temperature (min.)

+ 15 °C

Resistivity measuring range (max.)

10,00 MOhm*cm

Resistivity measuring range (min.)

1,00 Ohm*cm

Salinity measuring range (max.)

100 ppt

Salinity measuring range (min.)

0,01 ppm

TDS Factor (max)

1.00

TDS Factor (min)

0.40

TDS measuring range (max.)

500 g/l

TDS measuring range (min.)

0,1 mg/l

Temperature coefficent (max)

10,00 % / °C

Temperature coefficent (min)

0,00 % / °C

Temperature compensation

0,0...100,0 °C

Temperature measuring range (max.)

+ 120,0 °C

Temperature measuring range (min.)

- 20,0 °C

Temperature resolution

0,1 °C

Working temperature (max.)

+ 45 °C

Working temperature (min.)

0 °C

Feature

Analog view

Yes

Calibration report

Yes, printable. For pH parameters also graph report

Cell type

2 poles

DHS compatible

Yes

Display

Backlight coloured high definition TFT

Display

Backlight coloured high definition TFT

Electrode status indication

Yes, with icon

GLP

Yes

GLP

Yes

GLP calibration

Yes

Inputs

2 x BNC - 2 x RCA - banana 4 mm

ION calibration points

2...5

ION measuring unit

mg/l - g/l - mol/l

IP protection

IP 54

Memory

1000 data

Multilanguage

Eng - Ita - Deu - Esp - Fra - Cze

Online help

Yes

Output

USB - USB tipo B - RS232

Output

USB - USB tipo B - RS232

Password

Yes, 4 alphanumerical scripts

Password

Yes, 4 alphanumerical scripts

pH alarm range

Yes

Points of calibration Cond

1...4

Points of calibration pH

1...5 automatic values / 1...5 user values

Printer connection

Yes

Selectable Cell constant

0,1 / 1 / 10

Stability criteria

3 levels

Standard approved Cond

84 µS - 1413 µS - 12,88 mS - 111,8 mS / 1 user value

Standard approved pH

USA - NIST - DIN 19266 - 5 custom values

Timer calibration due

Yes

Ultrapure water compensation

Yes

Supply

Power supply

100 - 240 V / 50 - 60 Hz

Dimension and Weight

Dimension (LxWxH)

324 x 185 x 56 mm

Weight

1255 g