PC 8+ DHS STIRRER Bench with Polymer electrode and 2301T cell

Item: 50004142


PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangepH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);

Complete with XS Polymer S7 glass electrode, S7/BNC cable, NT 55 temperature probe, 2301T conductivity cell Epoxy with 2 electrodes (C=1) with built-in temperature probe, electrode holder, adjustable speed magnetic stirrer, colored pads, standard conductivity and power supply.


Data sheet

Regulations

Regulations

CE

Performance

Accuracy (Cond)

± 1 % f.s.

Accuracy (pH)

± 0,02

Accuracy (Salinity)

± 1 % f.s.

Accuracy (TDS)

± 1 % f.s.

Accuracy (Temperature)

± 0,2 °C

Cond measuring range (max.)

200 mS

Cond measuring range (min.)

0,00 µS

Cond resolution

0,01 / 0,1 / 1 µS/cm (automatic scale)

ORP measuring range (max.)

+ 2000

ORP measuring range (min.)

- 2000

ORP resolution

1 mV

pH measuring range (max.)

+ 16,00

pH measuring range (min.)

- 2,00

pH resolution

0,1 / 0,01

Reference temperature (max.)

+ 30 °C

Reference temperature (min.)

+ 15 °C

Salinity measuring range (max.)

100 ppt

Salinity measuring range (min.)

0,01 ppm

TDS Factor (max)

1.00

TDS Factor (min)

0.40

TDS measuring range (max.)

100 g/l

TDS measuring range (min.)

0.1 mg/l

Temperature coefficent (max)

10,00 % / °C

Temperature coefficent (min)

0,00 % / °C

Temperature compensation

0,0...100,0 °C

Temperature measuring range (max.)

+ 110,0 °C

Temperature measuring range (min.)

- 10,0 °C

Temperature resolution

0,1 °C

Working temperature (max.)

+ 45 °C

Working temperature (min.)

0 °C

Feature

Analog view

Yes

Calibration report

Yes, printable. For pH parameters also graph report

Cell type

2 poles

DHS compatible

Yes

Display

Backlight coloured high definition TFT

Display

Backlight coloured high definition TFT

GLP

Yes

GLP

Yes

GLP calibration

Yes

Inputs

2 x BNC - 2 x RCA - banana 4 mm

IP protection

IP 54

Memory

1000 data

Multilanguage

Eng - Ita - Deu - Esp - Fra - Cze

Output

USB - USB type B - RS232

Output

USB - USB type B - RS232

Password

Yes, 4 alphanumerical scripts

Password

Yes, 4 alphanumerical scripts

pH alarm range

Yes

Points of calibration Cond

1...4

Points of calibration pH

1...3 auto / 2 user values

Printer connection

Yes

Selectable Cell constant

0,1 / 1 / 10

Stability criteria

3 levels

Standard approved Cond

84 µS - 1413 µS - 12,88 mS - 111,8 mS - 1 user value

Standard approved pH

USA - NIST - 2 custom values

Timer calibration due

Yes

Supply

Power supply

100 - 240 V / 50 - 60 Hz

Dimension and Weight

Dimension (LxWxH)

324 x 185 x 56 mm

Weight

1255 g