Cond 60 VioLab bench-top conductivity meter complete with cell

Item: 50103072


Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity, TDS, Salinity measurement with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration and setting data
calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro-USB. Connection to external printer via RS232 connector.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
Cond: 0.0 microS ... 199.9 mS (0.01 microS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 (0.1 ° C)

Supplied as standard:
Electrode holder stand, conductivity standard, USB cable, power supply and instructions for use.

Complete with cell 2301T with built-in temperature sensor, 1m fixed cable.

Data sheet

Regulations

Regulations

CE

Performance

Accuracy (Cond)

± 2 % f.s.

Accuracy (Temperature)

± 0,5 °C

Cond measuring range (max.)

200 mS

Cond measuring range (min.)

0,00 µS

Cond resolution

0,01

Reference temperature (max.)

+ 30 °C

Reference temperature (min.)

+ 15 °C

Salinity measuring range (max.)

100 ppt

Salinity measuring range (min.)

0,1 ppm

TDS Factor (max)

1.00

TDS Factor (min)

0.40

TDS measuring range (max.)

200 g/l

TDS measuring range (min.)

0.1 mg/l

Temperature coefficent (max)

10,00 % / °C

Temperature coefficent (min)

0,00 % / °C

Temperature compensation

0,0...100,0 °C

Temperature measuring range (max.)

+ 110,0 °C

Temperature measuring range (min.)

- 10,0 °C

Temperature resolution

0,1 °C

Working temperature (max.)

+ 45 °C

Working temperature (min.)

0 °C

Feature

Calibration report

Yes, printable

Display

Backlight coloured high definition LCD

Display

Backlight coloured high definition LCD

GLP

Yes

GLP

Yes

Inputs

BNC - RCA

IP protection

IP 54

Memory

1000 data

Output

Micro USB - RS 232

Output

Micro USB - RS 232

PC connection

Yes

Points of calibration Cond

1...4

Stability filter

3 levels

Standard approved Cond

84 µS - 147 µS - 1413 µS - 12,88 mS - 111,8 mS - 1 user value

Timer calibration due

Yes

Supply

Power supply

100 - 240 V / 50 - 60 Hz

Dimension and Weight

Dimension (instrument)

160 x 140 x 45 mm

Instrument weight

380 g