COND 8+ STIRRER Without Cell
Item: 50003242
COND 8+ STIRRER
Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
Measurement range: Conductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);
Without cell, electrode holder, magnetic stirrer with adjustable speed, 2 calibration standards and power supply.
Data sheet
Regulations
Regulations
CE
Performance
Accuracy (Cond)
± 1 % f.s.
Accuracy (Salinity)
± 1 % f.s.
Accuracy (TDS)
± 1 % f.s.
Accuracy (Temperature)
± 0,2 °C
Cond measuring range (max.)
200 mS
Cond measuring range (min.)
0,00 µS
Cond resolution
0,01 / 0,1 / 1 µS/cm (automatic scale)
Reference temperature (max.)
+ 30 °C
Reference temperature (min.)
+ 15 °C
Salinity measuring range (max.)
100 ppt
Salinity measuring range (min.)
0,01 ppm
TDS Factor (max)
1.00
TDS Factor (min)
0.40
TDS measuring range (max.)
100 g/l
TDS measuring range (min.)
0.1 mg/l
Temperature coefficent (max)
10,00 % / °C
Temperature coefficent (min)
0,00 % / °C
Temperature compensation
0,0...100,0 °C
Temperature measuring range (max.)
+ 110,0 °C
Temperature measuring range (min.)
- 10,0 °C
Temperature resolution
0,1 °C
Working temperature (max.)
+ 45 °C
Working temperature (min.)
0 °C
Feature
Calibration report
Yes
Cell type
2 poles
Display
Backlight coloured high definition LCD
Display
Backlight coloured high definition LCD
GLP
Yes
GLP
Yes
Inputs
BNC - RCA
IP protection
IP 54
Memory
1000 data
Multilanguage
Eng - Ita - Deu - Esp - Fra - Cze
Output
USB - USB type B - RS232
Output
USB - USB type B - RS232
Password
Yes, 4 alphanumerical scripts
Password
Yes, 4 alphanumerical scripts
PC connection
Yes
Points of calibration Cond
1...4
Printer connection
Yes
Selectable Cell constant
0,1 / 1 / 10
Standard approved Cond
84 µS - 1413 µS - 12,88 mS - 111,8 mS / 1 user value
Stirring speed control
Stirrer with indipendent control
Timer calibration due
Yes
Supply
Power supply
100 - 240 V / 50 - 60 Hz
Dimension and Weight
Dimension (instrument)
324 x 185 x 56 mm
Instrument weight
1255 g