COND 8+ STIRRER Without Cell

Item: 50003242


COND 8+ STIRRER

Digital microprocessor bench-top conductivity meter with large backlit color graphic displayresolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangeConductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);

Without cell, electrode holder, magnetic stirrer with adjustable speed, 2 calibration standards and power supply. 

Data sheet

Regulations

Regulations

CE

Performance

Accuracy (Cond)

± 1 % f.s.

Accuracy (Salinity)

± 1 % f.s.

Accuracy (TDS)

± 1 % f.s.

Accuracy (Temperature)

± 0,2 °C

Cond measuring range (max.)

200 mS

Cond measuring range (min.)

0,00 µS

Cond resolution

0,01 / 0,1 / 1 µS/cm (automatic scale)

Reference temperature (max.)

+ 30 °C

Reference temperature (min.)

+ 15 °C

Salinity measuring range (max.)

100 ppt

Salinity measuring range (min.)

0,01 ppm

TDS Factor (max)

1.00

TDS Factor (min)

0.40

TDS measuring range (max.)

100 g/l

TDS measuring range (min.)

0.1 mg/l

Temperature coefficent (max)

10,00 % / °C

Temperature coefficent (min)

0,00 % / °C

Temperature compensation

0,0...100,0 °C

Temperature measuring range (max.)

+ 110,0 °C

Temperature measuring range (min.)

- 10,0 °C

Temperature resolution

0,1 °C

Working temperature (max.)

+ 45 °C

Working temperature (min.)

0 °C

Feature

Calibration report

Yes

Cell type

2 poles

Display

Backlight coloured high definition LCD

Display

Backlight coloured high definition LCD

GLP

Yes

GLP

Yes

Inputs

BNC - RCA

IP protection

IP 54

Memory

1000 data

Multilanguage

Eng - Ita - Deu - Esp - Fra - Cze

Output

USB - USB type B - RS232

Output

USB - USB type B - RS232

Password

Yes, 4 alphanumerical scripts

Password

Yes, 4 alphanumerical scripts

PC connection

Yes

Points of calibration Cond

1...4

Printer connection

Yes

Selectable Cell constant

0,1 / 1 / 10

Standard approved Cond

84 µS - 1413 µS - 12,88 mS - 111,8 mS / 1 user value

Stirring speed control

Stirrer with indipendent control

Timer calibration due

Yes

Supply

Power supply

100 - 240 V / 50 - 60 Hz

Dimension and Weight

Dimension (instrument)

324 x 185 x 56 mm

Instrument weight

1255 g