Models

COND 7+ complete instrument WITH CELL 2301T+ ATC

COND 7+

Conductivity portable meter with microprocessor. Simultaneous display of conductivity/TDS, Temperature and the values of buffers used for calibration. Function "Stability". Automatic scale change and automatic temperature compensation and manual (0 ... 80 °C). Adjustable reference temperature (15 ... 30 °C) and the cell constant (C = 0.1; 1; 10) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto-off, messages of self-diagnosis. Rubber cover with bench support. 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: (cell with C = 1 ) 0.0 ... 199.9 mS / TDS: 0...100 g/l  /  °C 0.0 ... 100.0 (0.1 °C)

Complete cell 2301T 2-electrode with integrated temperature sensor, standard solutions and instructions for use, in carrying case.

COND 7+TDS  INSTRUMENT without CELL

COND 7+ 

Conductivity portable meter with microprocessor. Simultaneous display of conductivity/TDS, Temperature and the values of buffers used for calibration. Function "Stability". Automatic scale change and automatic temperature compensation and manual (0 ... 80 °C). Adjustable reference temperature (15 ... 30 °C) and the cell constant (C = 0.1; 1; 10) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto-off, messages of self-diagnosis. Rubber cover with bench support. 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: (cell with C = 1 ) 0.0 ... 199.9 mS / TDS: 0...100 g/l  /  °C 0.0 ... 100.0 (0.1 °C)

Without cell 2301T but with standard solutions and instructions for use, in carrying case.

COND 70+ complete instrument WITH CELL 2301T+ ATC

COND 70+

Conductivity portable meter with microprocessor and triple power (via PC, network and battery) output with USB for PC connection. Large backlight display with 3 colours with simultaneous display of conductivity/TDS, temperature and values of buffers used for calibration. GLP with date and time of last calibration. Function "CAL TIMER" for setting the frequency of recalibration. Function "Stability". Automatic scale change and automatic temperature compensation and manual (0.0 ... 100 °C). The reference temperature (15 ... 30 ° C) and the cell constant (C = 0.1; 1; 10) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Data Logger with manual or automatic memory / recall up to 500 data with date and time. Rubber cover with bench support. Messages of self-diagnosis, Auto-Off . 5 year warranty on the electronics . IP57 Waterproof.

Measuring range: (cell with C = 1 ) Conductivity: 0 ... 199.9 mS / TDS: 0 ... 100 g/l / Salinity: 0 ... 50g/l / °C: -10.0 ... 110.0 °C

Complete cell 2301T 2-electrode with integrated temperature sensor, 1 m fixed cable, BNC plug and Cinch connector for temperature sensor, AC adapter 220V, PC-Link software with USB cable for data download to PC, buffers colourful and instructions for use, in carrying case.

COND 70+  INSTRUMENT without CELL

COND 70+

Conductivity portable meter with microprocessor and triple power (via PC, network and battery) output with USB for PC connection. Large backlight display with 3 colours with simultaneous display of conductivity/TDS, temperature and values of buffers used for calibration. GLP with date and time of last calibration. Function "CAL TIMER" for setting the frequency of recalibration. Function "Stability". Automatic scale change and automatic temperature compensation and manual (0.0 ... 100 ° C). The reference temperature (15 ... 30 ° C) and the cell constant (C = 0.1; 1; 10) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Data Logger with manual or automatic memory / recall up to 500 data with date and time. Rubber cover with bench support. Messages of self-diagnosis, Auto-Off . 5 year warranty on the electronics . IP57 Waterproof.

Measuring range: (cell with C = 1 ) Conductivity: 0 ... 199.9 mS / TDS: 0 ... 100 g/l / Salinity: 0 ... 50g/l / °C: -10.0 ... 110.0 °C

Without cell 2301T, but with 220V AC adapter, PC-Link software with USB cable for data download to PC, buffers colourful and instructions for use, in carrying case.