Models

PC 7+ DHS with Elect.201T + CELL 2301T + ATC

PC 7+ DHS

Multiparameter portable instrument with microprocessor for the measurement of pH, Conductivity, mV and Temperature. Manual or automatic temperature compensation probe NT 55. Visualization of the values of buffers used for calibration. In the scale pH / mV: function "Stability" and setting the criteria for stability of the measure (Low-Med-High). Automatic calibration up to 3 points. Buffers selectable NIST, USA (8 values) and two user-defined values. In the function COND: automatic change of scale, adjustable reference temperature (15 ... 30 °C) and cell constant (C = 0.1; 1; 10 ) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto Off. Rubber holster with bench support. Messages of self-diagnosis, 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: pH 0.00 ... 14.00 (0,1-0,01 pH); mV ± 1000 (1 mV); COND (cell with C = 1 ) 0.0 ... 199.9 mS; TDS: 0...100 g/l; °C 0.0 ... 100.0 (0.1 °C)

Complete of electrode 201 T with integrated temperature sensor, cell 2301T 2-electrode with integrated temperature sensor, both with 1m fixed cable, BNC plug and Cinch connector for temperature sensor, support from the field with 3 holes for electrodes, coloured buffers and instructions for use, in carrying case.

PC 7+ DHS with CELL 2301T + cable BNC + ATC without electrode

PC 7+ DHS

Multiparameter portable instrument with microprocessor for the measurement of pH, Conductivity, mV and Temperature. Manual or automatic temperature compensation probe NT 55. Visualization of the values of buffers used for calibration. In the scale pH / mV: function "Stability" and setting the criteria for stability of the measure (Low-Med-High). Automatic calibration up to 3 points. Buffers selectable NIST, USA (8 values) and two user-defined values. In the function COND: automatic change of scale, adjustable reference temperature (15 ... 30 °C) and cell constant (C = 0.1; 1; 10 ) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto Off. Rubber holster with bench support. Messages of self-diagnosis, 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: pH 0.00 ... 14.00 (0,1-0,01 pH); mV ± 1000 (1 mV); COND (cell with C = 1 ) 0.0 ... 199.9 mS; TDS: 0...100 g/l; °C 0.0 ... 100.0 (0.1 °C)

Without electrode but with temperature probe NT 55,cable S7 / BNC, cell 2301T 2-electrode with integrated temperature sensor with 1m fixed cable, BNC plug and Cinch connector for temperature sensor, support from the field with 3 holes for electrodes, coloured buffers and instructions for use, in carrying case.

PC 7+ DHS with Electrode 201T, WITHOUT Cell

PC 7DHS

Multiparameter portable instrument with microprocessor for the measurement of pH, Conductivity, mV and Temperature. Manual or automatic temperature compensation probe NT 55. Visualization of the values of buffers used for calibration. In the scale pH / mV: function "Stability" and setting the criteria for stability of the measure (Low-Med-High). Automatic calibration up to 3 points. Buffers selectable NIST, USA (8 values) and two user-defined values. In the function COND: automatic change of scale, adjustable reference temperature (15 ... 30 °C) and cell constant (C = 0.1; 1; 10 ) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto Off. Rubber holster with bench support. Messages of self-diagnosis, 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: pH 0.00 ... 14.00 (0,1-0,01pH); mV ± 1000 (1 mV); COND (cell with C = 1 ) 0.0 ... 199.9 mS; TDS: 0...100 g/l; °C 0.0 ... 100.0 (0.1 °C)

Without cell but with 201 T electrode with integrated temperature sensor, 1m fixed cable, BNC plug and Cinch connector for temperature sensor, support to field 3-hole electrode, coloured buffers and instructions for use, in carrying case.

PC 7+ DHS with BNC cable+ATC without Electrode, without Cell

PC 7+ DHS

Multiparameter portable instrument with microprocessor for the measurement of pH, Conductivity, mV and Temperature. Manual or automatic temperature compensation probe NT 55. Visualization of the values of buffers used for calibration. In the scale pH / mV: function "Stability" and setting the criteria for stability of the measure (Low-Med-High). Automatic calibration up to 3 points. Buffers selectable NIST, USA (8 values) and two user-defined values. In the function COND: automatic change of scale, adjustable reference temperature (15 ... 30 °C) and cell constant (C = 0.1; 1; 10 ) selectable. Automatic and manual calibration with automatic recognition of 4 standard (84; 1413 µS and 12,88; 111 mS) and one user-defined value. Auto Off. Rubber holster with bench support. Messages of self-diagnosis, 5-year warranty on the electronics. IP57 Waterproof.

Measuring range: pH 0.00 ... 14.00 (0,1-0,01pH); mV ± 1000 (1 mV); COND (cell with C = 1 ) 0.0 ... 199.9 mS; TDS: 0...100 g/l; °C 0.0 ... 100.0 (0.1 °C)

Without electrode and no cell but with temperature probe NT 55, cable S7 / BNC, support to field 3-hole electrode, coloured buffers and instructions for use, in carrying case.

PC 70+ DHS Complete with Elect.201T + CELL 2301T + ATC

PC 70+ DHS

portable Multiparameter for pH, mV, COND, TDS and Temperature measuraments. Triple power supply (PC, net anda batteries) with USB door. Automatic or manual temperature compensation with NT55 probe. Backlight display with 3 colours with viewing of buffers used for calibration. For pH / mV: "Stabilty" function and selectable measurement criteria's setting /Low-Med-High)., Automatic calibration up to 3 points according. Buffers selectable NIST, USA (8 values) or user definable (2 values). For Conductivity/TDS, automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 µS, 12,88 and 111 mS) 1 value defined by user. Automatic scale change. Reference temperature (15 ... 30 °C),  cell constant (C = 0.1 ... 10.0) selectable. "CAL TIMER" for frequency recalibration alarm, messages of self-diagnosis. Data Logger manual and automatic. Memory / recall up to 500 data with date / time according to GLP. USB to connect at the PC. 5 years warranty on the electronics part. IP57 waterproof.

Measuring range: pH -2,00 ... 16,00 (0.1-0,01 pH); mV -199,9 ... + 199,9 (0.1/1 mV); Conductivity (with cell C=1): 0.00 µS ... 199,9 mS; TDS: 0 ... 100.0 g/l; Salinity: 0...50 g/l; °C -10,0 ... +110.0 (0.1 °C);
 
Complete with electrode 201 T , cell conductivity 2301T  both with temperature probe integrated, 1 mt. cable BNC and Cinch plug for the temperature probe, support holder for 3 probe for field applications, power supply 220 V, software PC-Link with USB cable for downloading data on computer, coloured buffers and carrying case. 

PC 70+ DHS with CELL 2301T + cable BNC + ATC without electrode

PC 70+ DHS

Portable Multiparameter for pH, mV, COND, TDS and Temperature measurements. Triple power supply (PC, net anda batteries) with USB door. Automatic or manual temperature compensation with NT55 probe. Backlight display with 3 colours with viewing of buffers used for calibrationFor pH / mV: "Stabilty" function and selectable measurement criteria's setting /Low-Med-High)., Automatic calibration up to 3 points according. Buffers selectable NIST, USA (8 values) or user definable (2 values). For Conductivity/TDS, automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 µS, 12,88 and 111 mS) 1 value defined by user. Automatic scale change. Reference temperature (15 ... 30 °C),  cell constant (C = 0.1 ... 10.0) selectable. "CAL TIMER" for frequency recalibration alarm, messages of self-diagnosisData Logger manual and automatic. Memory / recall up to 500 data with date / time according to GLP. USB to connect at the PC. 5 years warranty on the electronics part. IP57 waterproof.

Measuring range: pH -2,00 ... 16,00 (0.1-0,01 pH); mV -199,9 ... + 199,9 (0.1/1 mV); Conductivity (with cell C=1): 0.00 µS ... 199,9 mS; TDS: 0 ... 100.0 g/l; Salinity: 0...50 g/l; °C -10,0 ... +110.0 (0.1 °C);
 
Complete with cell conductivity 2301T with temperature probe integrated, without electrode but with NT55 temperature probe, cable BNC and Cinch plug for the temperature probe, support holder for 3 probe for field applications, power supply 220 V, software PC-Link with USB cable for downloading data on computer, coloured buffers and carrying case. 

PC 70+ DHS with Electrode 201T, WITHOUT Cell

PC 70+DHS

portable Multiparameter for pH, mV, COND, TDS and Temperature measuraments. Triple power supply (PC, net anda batteries) with USB door. Automatic or manual temperature compensation with NT55 probe. Backlight display with 3 colours with viewing of buffers used for calibrationFor pH / mV: "Stabilty" function and selectable measurement criteria's setting /Low-Med-High)., Automatic calibration up to 3 points according. Buffers selectable NIST, USA (8 values) or user definable (2 values). For Conductivity/TDS, automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 µS, 12,88 and 111 mS) 1 value defined by user. Automatic scale change. Reference temperature (15 ... 30 °C),  cell constant (C = 0.1 ... 10.0) selectable. "CAL TIMER" for frequency recalibration alarm, messages of self-diagnosisData Logger manual and automatic. Memory / recall up to 500 data with date / time according to GLP. USB to connect at the PC. 5 years warranty on the electronics part. IP57 waterproof.

Measuring range: pH -2,00 ... 16,00 (0.1-0,01 pH)mV -199,9 ... + 199,9 (0.1/1 mV); Conductivity (with cell C=1): 0.00 µS ... 199,9 mS; TDS: 0 ... 100.0 g/l; Salinity: 0...50 g/l; °C -10,0 ... +110.0 (0.1 °C);
 
Complete with electrode 201 T temperature probe integrated, 1 mt. cable BNC and Cinch plug for the temperature probe, support holder for 3 probe for field applications, power supply 220 V, software PC-Link with USB cable for downloading data on computer, coloured buffers and carrying case. 

PC 70+ DHS with BNC cable+ATC without Electrode, without Cell

PC 70+ DHS

portable Multiparameter for pH, mV, COND, TDS and Temperature measuraments. Triple power supply (PC, net anda batteries) with USB door. Automatic or manual temperature compensation with NT55 probe. Backlight display with 3 colours with viewing of buffers used for calibrationFor pH / mV: "Stabilty" function and selectable measurement criteria's setting /Low-Med-High)., Automatic calibration up to 3 points according. Buffers selectable NIST, USA (8 values) or user definable (2 values). For Conductivity/TDS, automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 µS, 12,88 and 111 mS) 1 value defined by user. Automatic scale change. Reference temperature (15 ... 30 °C),  cell constant (C = 0.1 ... 10.0) selectable. "CAL TIMER" for frequency recalibration alarm, messages of self-diagnosisData Logger manual and automatic. Memory / recall up to 500 data with date / time according to GLP. USB to connect at the PC. 5 years warranty on the electronics part. IP57 waterproof.

Measuring range: pH -2,00 ... 16,00 (0.1-0,01 pH); mV -199,9 ... + 199,9 (0.1/1 mV); Conductivity (with cell C=1): 0.00 µS ... 199,9 mS; TDS: 0 ... 100.0 g/l; Salinity: 0...50 g/l; °C -10,0 ... +110.0 (0.1 °C);
 
Without electrode and conductivity cell  but with NT55 temperature probe and cable S7/BNC, support holder for 3 probe for field applications, power supply 220 V, software PC-Link with USB cable for downloading data on computer, coloured buffers and carrying case.