Models

COND 8+ BASIC with 2301T cell

COND 8+ BASIC

Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement range: Conductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);

Complete with 2301T epoxy conductivity cell with 2 electrodes (C = 1) with built-in temperature probe, electrode holder, 2 calibration standards and power supply. Without agitator.


COND 8 BASIC Without Cell, Without STIRRER

COND 8+ BASIC

Digital microprocessor bench-top conductivity meter with large backlit color graphic displayresolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangeConductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);

Without cell, with electrode holder, 2 calibration standards and power supply. Without agitator.


COND 8+ STIRRER With Cell 2301 T

COND 8+ STIRRER

Digital microprocessor bench-top conductivity meter with large backlit color graphic displayresolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangeConductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);

Complete with 2301T epoxy conductivity cell with 2 electrodes (C = 1) with built-in temperature probe, electrode holder, magnetic stirrer with adjustable speed, 2 calibration standards and power supply. 


COND 8+ STIRRER Without Cell

COND 8+ STIRRER

Digital microprocessor bench-top conductivity meter with large backlit color graphic displayresolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Numerical password for calibration management and memory cancellation. 1 USB output for PC connection. RS232 port for printer connection. Magnetic stirrer with independent control (optional). PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangeConductivity: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10.0 ... 110.0 (0.1 ° C);

Without cell, electrode holder, magnetic stirrer with adjustable speed, 2 calibration standards and power supply. 


COND 80+ STIRRER With Cell VPT 80-1

COND 80+ STIRRER

Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection. Magnetic stirrer with independent control (optional). Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measuring range: Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20.0 to 120.0 (0.1 ° C);

Complete with conductivity cell VPT 1 Platinum glass with 2 electrodes (C = 1) with built-in temperature probe, electrode holder, external keyboard, magnetic stirrer with adjustable speed, 2 calibration standards and power supply. 

COND 80+ STIRRER Without Cell

COND 80+ STIRRER 

Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection. Magnetic stirrer with independent control (optional). Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.


Measuring range: Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20.0 to 120.0 (0.1 ° C);

Without conductivity cell, complete with electrode holder support, external keyboard, adjustable speed magnetic stirrer, 2 calibration standards and power supply.

COND 80+ BASIC with VPT 80/1

COND 80+ BASIC

Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection. Magnetic stirrer with independent control (optional). Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measuring range: Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20.0 to 120.0 (0.1 ° C);

Complete with conductivity cell VPT 1 Platinum glass with 2 electrodes (C = 1) with built-in temperature probe, electrode holder, external keyboard, 2 calibration standards and power supply. Without magnetic stirrer.

COND 80+ BASIC without conductivity cell

COND 80+ BASIC

Digital microprocessor bench-top conductivity meter with large backlit color graphic display, resolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Self-diagnosis messages, input for cells with 2 electrodes. Intuitive management of parameters via icons. Italian multilingual menu included. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Indication of the stability of the measurement. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection. Magnetic stirrer with independent control (optional). Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measuring range: Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20.0 to 120.0 (0.1 ° C);

Without conductivity cell, complete with electrode holder stand, external keyboard, 2 calibration standards and power supply. Without magnetic stirrer.

Cond 50 VioLab bench-top conductivity meter complete with cell

Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity measurement, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
Cond: 0.0 microS ... 199.9 mS (0.01 microS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... + 100.0 (0.1 ° C)

Supplied as standard:
Electrode holder stand, conductivity standard, power supply and instructions for use.

Complete with cell 2301T with built-in temperature sensor, 1m fixed cable.

Cond 50 VioLab bench-top conductivity meter without cell

Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity measurement, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
Cond: 0.0 microS ... 199.9 mS (0.01 microS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... + 100.0 (0.1 ° C)

Supplied as standard:
Electrode holder stand, conductivity standard, power supply and instructions for use.

Instrument with accessories, without cell

Cond 60 VioLab bench-top conductivity meter complete with cell

Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity, TDS, Salinity measurement with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration and setting data
calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro-USB. Connection to external printer via RS232 connector.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
Cond: 0.0 microS ... 199.9 mS (0.01 microS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 (0.1 ° C)

Supplied as standard:
Electrode holder stand, conductivity standard, USB cable, power supply and instructions for use.

Complete with cell 2301T with built-in temperature sensor, 1m fixed cable.

Cond 60 VioLab bench-top conductivity meter without cell

Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity, TDS, Salinity measurement with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration and setting data
calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro-USB. Connection to external printer via RS232 connector.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

Measuring range:
Cond: 0.0 microS ... 199.9 mS (0.01 microS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 (0.1 ° C)

Supplied as standard:
Electrode holder stand, conductivity standard, USB cable, power supply and instructions for use.

Instrument with accessories, without cell.