MULTIPARAMETERS

The Multiparameter Instruments enclose in only one pHmeter and conductivimeter functions, in this way we take advantage in terms of space, functionality and price.
Also for this type of instrument exist portable and bench version.

The XS Instruments line has portable (and bench, of course) with multiparameter function, like:

pH 7 Vio + COND 7 Vio --> PC 7 Vio

pH 70 Vio + COND 70 Vio --> PC 70 Vio

The same example is possible with bench line.
Also in this case, technical data change by simple instrument to professional one.

The PC 7 Vio is the simple instrument for a fast and accurate reading on the field.

The PC 70 Vio allows values recording and transferring data to the PC to analyse and produce report with data collected.

These instruments, in combination with sensor connected, allow measurement of pH / mV / Cond / TDS / SAL (only PC 70 Vio) and temperature in only one instrument.
Even if these instruments are a combination of different parameters, they keep a simple usability through the same keys and functions of monoparameter instrument.

Of course, all these products are Made in Italy

Benchmeters

PC 8+ DHS STIRRER with STANDARD T-BNC DHS electrode and 2301T cell

PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement range: pH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);

Complete with XS Standard T-BNC DHS digital pH electrode, S7/BNC cable, NT 55 temperature probe, 2301T epoxy conductivity cell with 2 electrodes (C=1) with built-in temperature probe, electrode holder, adjustable speed magnetic stirrer, colored pads, standard conductivity and power supply.

PC 8+ DHS STIRRER Bench with Polymer electrode and 2301T cell

PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangepH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);

Complete with XS Polymer S7 glass electrode, S7/BNC cable, NT 55 temperature probe, 2301T conductivity cell Epoxy with 2 electrodes (C=1) with built-in temperature probe, electrode holder, adjustable speed magnetic stirrer, colored pads, standard conductivity and power supply.


PC 8+ DHS STIRRER Bench With CELL Without electrode

PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangepH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);


Without pH electrode, S7/BNC cable, temperature probe NT 55, with cell conductivity epoxy 2301T 2-electrode (C = 1) with temperature probe integrated, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars and power supply.

PC 8+ DHS STIRRER Bench With electrode Polymer Without CELL

PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangepH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);

Complete with glass electrode XS Polymer S7, S7/BNC cable, temperature probe NT 55, no cell conductivity, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars and power supply.

PC 8+ DHS STIRRER Without electrode Without CELL

PC 8+ DHS STIRRER

Multiparameter pH, mV, COND, TDS, Salinity, Temperature, microprocessor digital benchtop instrument, resolution ± 0.1 / 0.01 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous display of pH / COND and temperature. Automatic calibration from 1 to 3 points for pH according to GLP with date and time. Selectable NIST, USA and user definable buffers (2 values). Calibration report and innovative graphic representation. Display of the buffers used for calibration on the display. Manual or automatic temperature compensation with NT 55 probe. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a standard defined by the 'user. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%), Selectable cell constant (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Manual and automatic Data Logger function. Memory / recall up to 1000 data with date / time according to GLP. Intuitive management of parameters via icons. Multilingual menu. Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode, recalibration alarm, self-diagnosis messages. USB output for PC connection and RS232 port for printer connection. Numerical password for management of calibration and cancellation of memory. Magnetic stirrer with independent control. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.

Measurement rangepH -2.00 ... 16.00 (0.01 pH); mV-2000 ... + 2000 (1 mV); COND: 0.00 μS ... 200.0 mS; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 100.0 g / l; °C -10 ... 110.0 (0.1 ° C);


Without pH electrode and no cell
, with S7/BNC cable, temperature probe NT 55, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars and power supply.

PC 80+ DHS STIRRER with cell VPT 80/1 with Standard T-BNC DHS electrode

PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Temperature microprocessor digital benchtop meter, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic Data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement range: pH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); COND: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Complete with XS Standard T-BNC DHS pH electrode, VPT 1 conductivity cell Platinum glass with 2 electrodes (C=1) with built-in temperature probe, S7 / BNC cable, NT 55 temperature probe, electrode holder, external keyboard, magnetic stirrer with adjustable speed, colored pH buffers, standard conductivity and power supply. 

PC 80+ DHS STIRRER With Cell VPT 80-1 and electrode Standard

PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement range: pH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Complete with XS Standard pH electrode, VPT 1 conductivity cell Platinum glass with 2 electrodes (C = 1) with built-in temperature probe, S7 / BNC cable, NT 55 temperature probe, electrode holder, external keyboard, magnetic stirrer with adjustable speed, colored pH buffers, standard conductivity and power supply.

PC 80+ DHS STIRRER Bench With Cell VPT 80-1 Without electrode

PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement rangepH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Without pH electrode, cable S7 / BNC, temperature probe NT 55, with cell conductivity VPT 1 glass Platinum 2-electrode(C = 1) with temperature probe integrated, support holders, magnetic stirrer with adjustable speed, buffers coloured,glasses for calibration with stirring bars, software for downloading data and power supply.

PC 80+ DHS STIRRER With electrode Standard Without Cell

PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement rangepH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Complete with glass electrode XS Standard S7
, S7/BNC cable, temperature probe NT 55, no cell conductivity, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars , software for downloading the data and power supply.

PC 80+ DHS STIRRER Without electrode Without CELL

PC 80+ DHS STIRRER

Multi parameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 μS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date / time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display on the display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display on the display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID and sensor ID via external keyboard (included). Alarm setting and display functions in analogue format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection.
Magnetic stirrer with independent control. Quick manual online. PC software downloadable for free. IP54 keyboard, warranty on the electronic part of 3 years.
 

Measurement rangepH -2,000 ... 20,000 (0,001 pH); mV -2000 ... + 2000 (0.1 mV); Conductivity: 0.00 μS ... 1000.0 mS; Resistivity: 1 O ... 10 MW; Salinity: 0.01 ... 100.0 ppt; TDS: 0.1 mg / l ... 500.0 g / l; °C -20 ... 120.0 (0.1 ° C);

Without pH electrode and no cell, with cable S7/BNC, temperature probe NT 55, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars, software for downloading data and power supply.

PC 50 VioLab bench-top multiparameter with 2301T cell and 201T DHS electrode

Professional bench multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: -1000 ... + 1000 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, power supply and instructions for use.

With 201T DHS electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 50 VioLab bench-top multiparameter with 2301T and 201T electrode

Professional bench multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: -1000 ... + 1000 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, power supply and instructions for use.

With 201T electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 50 VioLab bench-top multiparameter with 2301T cell without electrode

Professional bench multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: -1000 ... + 1000 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, power supply and instructions for use.

Without pH electrode.
With 2301T cell
, NT 55 temperature probe, S7-BNC cable and accessories. 

PC 60 VioLab bench-top multiparameter with electrode 201T and 2301T cell

Professional bench-top multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration expiration setting. Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
Connection to external printer via RS232 connector.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, USB cable for data download to PC, power supply and instructions for use.

With 201T electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 60 VioLab bench-top multiparameter with 2301T cell without electrode

Professional bench-top multiparameter with innovative high definition color LCD display, with possibility of brightness adjustment.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration expiration setting. Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
Connection to external printer via RS232 connector.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Electrode holder stand, colored buffer solutions, USB cable for data download to PC, power supply and instructions for use.

Without pH electrode.
With 2301T cell
, NT 55 temperature probe, S7-BNC cable and accessories.

IP 67 waterproof case for Vio portable instruments

IP 67 waterproof case for Vio portable instruments

Portable

PC 7 Vio multiparameter with 201T Electrode and 2301T Cell

Professional portable multiparameter with innovative high resolution color display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and illumination of the display.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display and the possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: –1000… + 1000 (0.1 mV)
Cond: 0.01 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions,
instructions for use and carrying case.

With 201T electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 7 Vio multiparameter with 2301T Cell without electrode

Professional portable multiparameter with innovative high resolution color display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and illumination of the display.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display and the possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: –1000… + 1000 (0.1 mV)
Cond: 0.01 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions,
instructions for use and carrying case.

Without electrode.
With 2301T cell
, NT 55 temperature probe, S7-BNC cable and accessories. 

PC 7 Vio multiparameter without sensors

Professional portable multiparameter with innovative high resolution color display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and illumination of the display.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display and the possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: –1000… + 1000 (0.1 mV)
Cond: 0.01 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions,
instructions for use and carrying case.

Without pH electrode and conductivity cell; with NT 55 temperature probe, S7-BNC cable and accessories. 

PC 7 Vio portable multiparameter with 201T DHS electrode and 2301T cell

Professional portable multiparameter with innovative high resolution color display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and illumination of the display.
Measurement of pH, mV, ORP, Conductivity, TDS, with temperature display and the possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: 0.00 ... 14.00 (0.01 pH)
mV: –1000… + 1000 (0.1 mV)
Cond: 0.01 µS ... 200 mS (0.01 µS - automatic)
TDS: 0.01 mg / l ... 200 g / l
Temperature: 0 ... 100.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions,
instructions for use and carrying case.

With 201T DHS digital electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 70 Vio Complete with 201T Electrode and 2301T Cell

Professional portable multiparameter with triple power supply (battery, PC, mains) with innovative high resolution color display, for excellent data visualization in all cooling conditions, also thanks to the possibility of automatically and manually adjusting control and lighting of the screen.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display and possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration notification.
Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions, USB cable, power supply, instructions for use and carrying case.

With 201T electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

PC 70 Vio with 2301T Cell without electrode

Professional portable multiparameter with triple power supply (battery, PC, mains) with innovative high resolution color display, for excellent data visualization in all cooling conditions, also thanks to the possibility of automatically and manually adjusting control and lighting of the screen.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display and possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration notification.
Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions, USB cable, power supply, instructions for use and carrying case.

Without electrode.
With 2301T cell, NT 55 temperature probe, S7-BNC cable and accessories. 

PC 70 Vio without electrode and without electrode

Professional portable multiparameter with triple power supply (battery, PC, mains) with innovative high resolution color display, for excellent data visualization in all cooling conditions, also thanks to the possibility of automatically and manually adjusting control and lighting of the screen.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display and possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration notification.
Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions, USB cable, power supply, instructions for use and carrying case.

Without electrode and without 2301T cell; with NT 55 temperature probe, S7-BNC cable and accessories. 

PC 70 Vio Complete with 201T DHS Electrode and 2301T Cell

Professional portable multiparameter with triple power supply (battery, PC, mains) with innovative high resolution color display, for excellent data visualization in all cooling conditions, also thanks to the possibility of automatically and manually adjusting control and lighting of the screen.
Measurement of pH, mV, ORP, Conductivity, TDS, Salinity with temperature display and possibility to select the parameters you want to view.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers up to 3 points and 2 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 5 points and a user-defined point.
Indication with icons of the calibrated points.
Measurement stability indicator and possibility to select 3 stability levels.
GLP functions: Date and time, display of calibration data and calibration notification.
Manual and automatic Data Logger with the possibility of downloading data to PC via micro USB.
Data-Link software freely downloadable from www.giorgiobormac.com.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and the self-diagnosis messages.

Measuring range:
pH: -2.00 ... 16.00 (0.01 pH)
mV: -1000 ... + 1999 (0.1 mV)
Cond: 0.0 µS ... 200 mS (0.01 µS - automatic)
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.01 mg / l ... 200 g / l
Temperature: -10 ... + 110.0 ° C (0.1 ° C)

Supplied as standard:
Field support with 3 holes for electrodes, colored buffer solutions, USB cable, power supply, instructions for use and carrying case.

With 201T DHS electrode and 2301T cell, both with built-in temperature sensor and 1 m fixed cable.

XS Revio Multiparameter - 201 T Electrode, 2301T Cell, polarographic DO Sensor

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

With 201 T electrode2301T cell and polarographic oxygen sensor, built-in temperature sensor and 3 m fixed cable, in rigid case.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)

XS Revio Multiparameter - 201 T Electrode, polarographic DO Sensor 

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

With 201 T electrode and polarographic oxygen sensor, built-in temperature sensor and 3 m fixed cable, in rigid case.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)

XS Revio Multiparameter - Only instrument with accessories

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

Instrument in rigid case, with NT 55 temperature probe 3 meter cable, S7-BNC cable and accessories. WITHOUT SENSORS.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)

XS Revio Multiparameter - 2301T Cell, polarographic DO Sensor

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

With 2301T cell and polarographic oxygen sensor, built-in temperature sensor and 3 m fixed cable, in rigid case.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)

XS Revio Multiparameter - 201 T DHS Electrode, 2301T Cell, Polarographic DO Sensor

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

With 201 T DHS digital electrode, 2301T cell and polarographic oxygen sensor, built-in temperature sensor and 3 m fixed cable, in rigid case.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)

XS Revio Multiparameter - 201 T Electrode, 2301T Cell, polarographic DO Sensor _ SOFT CASE

Professional portable multiparameter with triple power supply (battery, PC, mains) with backlit color graphic display, for excellent data visualization in all lighting conditions, thanks also to the possibility of automatically and manually adjusting the contrast and lighting of the display.
Measurement of pH, mV, ORP, ISE, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and Temperature.
The online help in setup and calibration allows a simple and immediate use of the device.
Simultaneous display of multiple parameters, chosen by the operator.
Automatic pH calibration with USA and NIST buffers up to 5 points and 5 points defined by the user.
Automatic ORP calibration 1 point.
Automatic calibration of conductivity up to 4 points and 1 point defined by the user.
Adjustable reference temperature and selectable cell constant.
Automatic O2 calibration up to two points (0% - 100%).
Indication with icons of the calibrated points.
GLP functions: Date and time, display of calibration data and setting of calibration deadline.
Manual and automatic data logger with the possibility of downloading data to PC via micro USB.
Data Link software freely downloadable from www.giorgiobormac.com.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and signaled to the operator via the colored LED above the display and self-diagnosis messages.

With 201 T DHS digital electrode2301T cell and polarographic oxygen sensor, built-in temperature sensor and 3 m fixed cable, in PURSE WITH SHOULDER STRAP.



Measuring range:
pH: -2.000 ... 20.000 (0.001 pH)
mV: –2000… + 2000 (0.1 mV)
ISE: 0.001 ... 19999 ppm
Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
Resistivity: 1 Ω ... 20 MΩ
Salinity: 0.1 ppm ... 100 ppt
TDS: 0.1 mg / l ... 500.0 g / l
DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
Saturation: 0.0… 400% (0.1 / 1%)
Barometric pressure: 0… 1100 mbar (1 mbar)
Temperature: -30 ... 130.0 ° C (0.1 ° C)